Pocket test measures fifty things in a drop of blood

Dec. 19, 2012 ? A new device about the size of a business card could allow health care providers to test for insulin and other blood proteins, cholesterol, and even signs of viral or bacterial infection all at the same time -- with one drop of blood. Preliminary tests of the V-chip, created by scientists at The Methodist Hospital Research Institute and MD Anderson Cancer Center, were just published by Nature Communications.

"The V-Chip could make it possible to bring tests to the bedside, remote areas, and other types of point-of-care needs," said Nanomedicine faculty member Lidong Qin, Ph.D., the project's principal investigator. "V-Chip is accurate, cheap, and portable. It requires only a drop of a sample, not a vial of blood, and can do 50 different tests in one go."

Similar assays are typically done using heavy, large, complex equipment such as mass spectrometers, or require fluoroscopy analysis, which must also be done in a lab.

The V-chip, short for "volumetric bar-chart chip," on the other hand, can be carried around in a pocket. It is composed of two thin pieces of glass, about 3 in. by 2 in. In between are wells for four things: (1) hydrogen peroxide, (2) up to 50 different antibodies to specific proteins, DNA or RNA fragments, or lipids of interest, and the enzyme catalase, (3) serum or other sample, and (4) a dye -- any dye will do. Initially, the wells are kept separate from each other. A shift in the glass plates brings the wells into contact, creating a contiguous, zig-zagged space from one end of the V-chip to the other.

As the substance of interest -- say, insulin -- binds to antibodies bound to the glass slide, catalase is made active and splits nearby hydrogen peroxide into water and oxygen gas. This approach is called ELISA, or enzyme-linked immunosorbent assay. The oxygen pushes the dye up the column. The more present insulin is, the more oxygen is created, and the farther dye is pushed up the slide. Tests show that distance is more or less proportional to the amount of substrate present, in this example, insulin. The end result is a visual bar chart. Easy to read and accurate, Qin says, though development continues.

"The sensitivity of the V-chip can be improved if narrower and longer bar channels are used," Qin said. "Our next steps are to make the device more user friendly and be so simple to use, it barely needs instructions."

Qin is also a Weill Cornell Medical College assistant professor of cell and developmental biology.

Share this story on Facebook, Twitter, and Google:

Other social bookmarking and sharing tools:


Story Source:

The above story is reprinted from materials provided by Methodist Hospital, Houston, via Newswise.

Note: Materials may be edited for content and length. For further information, please contact the source cited above.


Journal Reference:

  1. Yujun Song, Yuanqing Zhang, Paul E. Bernard, James M. Reuben, Naoto T. Ueno, Ralph B. Arlinghaus, Youli Zu, Lidong Qin. Multiplexed volumetric bar-chart chip for point-of-care diagnostics. Nature Communications, 2012; 3: 1283 DOI: 10.1038/ncomms2292

Note: If no author is given, the source is cited instead.

Disclaimer: This article is not intended to provide medical advice, diagnosis or treatment. Views expressed here do not necessarily reflect those of ScienceDaily or its staff.

Source: http://feeds.sciencedaily.com/~r/sciencedaily/top_news/top_technology/~3/beKv54NZu-g/121219152621.htm

fbi most wanted list stuttering james van der beek dyngus day indonesia quake stephen strasburg shabazz

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.